Description
Hohm DEPOT is tailor-made to push where other batteries fall. It focuses on maintaining everything one would expect of Hohm Tech cells while simultaneously reducing the cost per unit of Ah. R&D started in early 2020, with prototype testing by late 2020 and throughout 2021. With minor, mild, and unique formulation adjustments, Hohm DEPOT can confidently surpass other ≈3Ah (3000mAh) cells. A highly-positive result in the cell honing comes improved cycle life (via UL test standard). This occurred by simply switching from the QSP to DSP (Quad vs. Dual Stripping Process).
As for the nitty-gritty…these are rated at 3005mAh capacity, with a CDR of 16.8A, and 80oC | 3.2V cut-off limit (whichever occurs first) @ 22.5A. For DC motor and inverter-only applications, the DEPOT cell handles 28.4A for 5s on, 30s off. Note: 28.4A limitation is solely for DC motor and inverter applications only. All ratings are subject to meet and/or exceed strict limitation policies set forth for DLr1, TID2, PVDL3, CLR4, mΩR5, and Temperature (°C). Hohm DEPOT is built from the DSP NMC chemistry formulation, with manganese inert compound replaced with additional proprietary levels of cobalt & nickel as well as added custom bonding agents to achieve unprecedented U.D.O.S. results. It is further enhanced with components from industry-leading manufacturers that give it the heartbeat of Hohm Tech.
Every Hohm Tech Int’l cell model has been tested and certified by UN38.3, EN62133, IEC62133 2nd Edition, and UL1642 accredited laboratories and testing facilities assigned by regulatory bodies. This includes MSDS, CE, ROHS, UN38.3, IEC, PSE, Specifications, and Air/Sea Transport certifications. We do not cut corners. We deliver what we promise… chart-topping performance, capacity, consistency, and safety.
To expound on safety:
• modified cathode tag consisting of higher purity aluminum is utilized to aid in lowering internal resistance
• updated poly seal with refined bitumen is installed in every cell to ensure excess pressure is controlled
* NOTICE: Hohm Tech Int’l does not manufacture batteries. These are made for and licensed to Hohm Tech Int’l achieving their requirements set forth.
** CAN BE CHARGED AT 3.6A. This is not a misprint. 3.6A as in THREE POINT SIX-amp charging is possible, tested, proven, and approved within all strict safety protocols set forth.
*** TESTING BEYOND TEMPERATURE. Hohm Tech cells utilize both static & dynamic testing that includes but not limited to: density loss, thermal distribution, volt drop limiters, cycle life retention, and temperature. These tests are imperative to achieve true cell performance, longevity, and overall quality.
1 Density Loss Ratio
2 Thermal Image Distribution
3 Pulse Voltage Drop Limitation
4 Cycle Life Retention
5 Resistance Retentivity Pre|Post
6 Surge/Pulse is applicable to Dynamic EV Systems ONLY and rated @ ≤5 SEC ON / ≥30 SEC OFF
WARNING: LI-ION CELLS HAVE INHERENT RISKS IF MISUSED OR MISHANDLED. CELL CAN EXPLODE CAUSING SEVERE BURN INJURY, FATALITY, AND PROPERTY DAMAGE. – READ BELOW THOROUGHLY –
READ BROCHURE HERE
CELL = BATTERY
- KEEP OUT OF REACH of minors (at least 18 years of age) and pets.
- DO NOT PUT IN FIRE, oven, microwave, or expose to anything over 100oC (212oF)
- DO NOT CARRY or store OUTSIDE of its protective packaging or a PROTECTIVE CELL CASE. The protective cell case must PREVENT CELLS FROM TOUCHING ONE ANOTHER. UNDER NO CIRCUMSTANCE is a protective case to be put in a pocket, bag, purse, or on your body. A protective case can be carried by hand in a controlled manner and/or stored where it is not subjected to movement or extreme temperatures.
- DO NOT PUT IN POCKET, bag, purse, or on your body (applicable at all times and in all circumstances). Pockets contain KEYS, COINS, OBJECTS, and/or DEBRIS that can short-circuit a cell (battery) that can result in an explosion. The cell is to be stored in its protective packaging or a protective case that prevents cells from touching one another. UNDER NO CIRCUMSTANCE ARE CELLS (batteries) TO BE PUT IN A POCKET, bag, purse, or on your body. With cell(s) in a protective case, carry by hand or store where cell(s) are not subjected to movement.
- DO NOT PUT A DEVICE WITH CELL(S) INSTALLED IN IT IN YOUR POCKET or ON YOUR BODY. As unlikely as it may be, a device can malfunction and/or be affected by debris or object(s) in the pocket that can short-circuit a cell causing it to explode. Additionally, removable-battery devices enable the cell(s) to move/shift inside a device which can subject cell(s) to condition(s) that put wear and tear on a cell’s protective label/wrap/skin barrier. This can lead to a short-circuit and potential explosion. Being in a pocket subjects the device (and cell(s)) to abrupt and jarring movements. Carrying and using the device with hand(s) is proper. ** Hohm Tech encourages to use a fire-retardant case/enclosure to carry device(s) with cell(s) installed inside it (applicable to device(s) with external and/or removable cell(s)).
- DO NOT USE IN A DEVICE THAT CAN EXCEED MAX CELL WATTAGE (W) or AMPERAGE (A) (listed on each cell and retail packaging). Otherwise, this can overload a cell, causing it to explode.
- DO NOT USE A LOWER RESISTANCE (Ω) # (listed on each cell and retail packaging). Otherwise, this can overload cell, causing it to explode.
- DO NOT USE CELL WITH ANY DAMAGE TO ITS STRUCTURE OR OUTER PROTECTIVE LABEL (also called “WRAP”, “sleeve”, “skin”). Damage may include: dent(s), tear(s), nick(s), puncture(s), corrosion, or any other undisclosed abnormalities or damages. Otherwise, a cell can short-circuit and explode. ALWAYS INSPECT cell VISUALLY and by TOUCH to SEE/FEEL for damage BEFORE EACH USE. ** SEE THE ILLUSTRATION BELOW AS A GUIDELINE. **
- DO NOT LEAVE UNATTENDED WHILE CHARGING, & IMMEDIATELY REMOVE CELL(s) FROM CHARGER ONCE FULLY CHARGED to ensure it is not exposed to any potential charger malfunction such as overcharging which could damage the cell causing it to explode.
- DO NOT CHARGE HIGHER THAN MAX CHARGE VOLTAGE (V) (typically 4.2V) or DISCHARGE BELOW MAX VOLTAGE CUT-OFF (V) (typically 2.5V). Overcharging or over-discharging cell(s) can cause irreversible damage and cause it to explode.
- DO NOT MIX WITH USED or DIFFERENT BATTERY TYPES. Differences in cell capacity can lead to one or more cell(s) being overcharged or over-discharged.
- IF USING A MULTI-CELL DEVICE, the device MUST HAVE A NON-CONDUCTIVE BARRIER (typically plastic) OR FITMENT that PREVENTS CELL(S) from TOUCHING THE SIDE(S) OF ONE ANOTHER OR ANY ADJACENT METAL except for the very center of top and bottom of the cell. Otherwise, cell(s) could short-circuit and explode.
- ALWAYS REPLACE CELL when capacity has decreased or within a maximum of 12 months of use (whichever occurs first) when used in a device that allows cell(s) to be changed/removed. Cell degradation and wear incurred from repeated installation/removal can negatively impact cell integrity and subject it to conditions that can cause it to be short-circuited and explode.
- ALWAYS charge, connect, and operate cell(s) within their capabilities as listed on each cell, packaging, and all product detail pages, while adhering to the device’s user manual.
- COMPLETELY READ and follow the WARNING section listed on each cell, packaging, and here, in its entirety.
- SEARCH www.YouTube.com for “18650 EXPLOSIONS” to understand the importance of consistently taking safety precautions and using Li-ion cells properly. Hohm Tech advocates recycling and replacing any damaged Li-ion cell/battery. As a tool to find your LOCAL RECYCLE CENTER. Or visit Hohm Tech Warranty Center for recycling and replacement. Your safety is #1.
Write A Reviews